New and improved technical tools Imaging lens selector Visit
Product classification
GCD-730101M High precision motorized goniometer stage
GCD-730101M High Precision Motorized Goniometer Stage
GCD-730101M High precision motorized goniometer stage employs precision worm gear as the actuation component, crossed roller bearing as the guide way, rely on which Daheng’s goniometer stage features high accuracy and outstanding repeatability, as well as high loading capacity.
The 70mmX70mm rotary platform rotates on a transverse axis that is 96mm above the horizontal position of the platform. GCD-730101M provides a travel range of ±10°. The reset function (GCD-0401 motorized stage controller) helps to return the platform to a horizontal position(0°)rapidly and conveniently, facilitates complex operations. Moreover, GCD-730101M equipped with an angle scale which has a main scale of 1°, and a vernier scale of 0.1°. In other words, the users may obtain a decimal angular displacement by manual operation.
GCD-730101M High Precision Motorized Goniometer Stage
Part No. |
Size (mmxmmxmm) |
Rotating Center(mm) |
Platform Size (mmxmm) |
Travel |
Accuracy |
Bi-directional Repeatability |
GCD-730101M |
184x88.5x35 |
96 |
70x70 |
±10° |
0.05° |
±0.004° |
© 2019 Daheng New Epoch Technology,Inc. 京ICP备05081235号-2